{"product_id":"kwik-e-vac-line-set-flushing-kit-installation-simplifier-for-mini-split-air-conditioning-systems","title":"KWIK-E-VAC Line Set Flushing Kit Installation Simplifier for Mini Split Air Conditioning Systems","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3\u003eSummary\u003c\/h3\u003e\n\u003cul class=\"a-unordered-list a-vertical a-spacing-none\"\u003e\n\u003cli\u003e\u003cspan\u003eFlush the air and other non-condensable gases out of the copper line set and indoor unit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAlternative for the inefficient and expensive quick-connect line sets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCost-effective, simple, and quick evacuation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for most people and installations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"a-list-item\"\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003ePioneer KWIK-E-VAC is an all-new, revolutionary, patented kit designed to simplify the installation process. This product is \u003cstrong\u003eintended to provide an alternative to a vacuum pump\u003c\/strong\u003e, a tool that was previously required to install mini splits. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKWIK-E-VAC works by flushing the air and other non-condensable gases out of the copper line set and indoor unit combination, in order to ensure that the refrigerant in the system remains contaminant-free. In order to bleed the lines of any air and check for leaks, a vacuum pump and pressure gauges were previously needed. This kit allows the user to bypass that step, making any mini-split system truly DIY.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eUse this as an alternative for the inefficient and expensive quick-connect line sets, which reduce system efficiency and capacity, and cost 10 times more than the cost of this kit. A cost-effective, simple, and quick evacuation, perfect for most people and installations.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTapless bottle weights 4 oz when empty.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ZDXIIJwDkM8\" target=\"_blank\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003eDirections of use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis kit provides an alternative way to install a split air conditioner, if a proper vacuum pump is not available for the evacuation of the line sets. See below instructions, only to replace the specific section in the installation manual covering the use of a vacuum pump for evacuation. Follow all remaining instructions in the manual as originally written.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eRead all safety instructions above and wear protective gear as suggested.\u003c\/li\u003e\n\u003cli\u003eKeep the metal can upright at all times while using. Do not tilt or tip.\u003c\/li\u003e\n\u003cli\u003eEnsure the electrical power to entire equipment is switched off at the main breaker.\u003c\/li\u003e\n\u003cli\u003eIndoor section of the air conditioner: Connect both copper pipes of the line set to the indoor unit properly and as instructed in the equipment installation manual, using proper torque, methods, and materials approved by the equipment manufacturer.\u003c\/li\u003e\n\u003cli\u003eOutdoor section of the air conditioner: Connect ONLY THE GAS SIDE copper pipe (one with larger diameter) to the GAS side service valve of the outdoor unit properly and as instructed in the equipment installation manual, using proper torque, methods and materials approved by the equipment manufacturer. Do not connect the LIQUID SIDE copper pipe (one with smaller diameter) at this time, until instructed further below.\u003c\/li\u003e\n\u003cli\u003eConnect the end connector of hose of the purging kit to the SERVICE PORT on the GAS SIDE SERVICE VALVE of the outdoor unit tightly. Pay attention to prevent valve damage.\u003c\/li\u003e\n\u003cli\u003eTurn the valve on the flushing kit can tap valve clockwise, reaching all the way down.\u003c\/li\u003e\n\u003cli\u003eYou should hear the flow of flushing material flowing into the GAS side of the copper line set and then flowing out freely at unconnected pipe end of the LIQUID side of the copper line set near the outdoor unit. Once flow is confirmed, close the tap valve, then open again for 5 seconds at a time, repeating until about 2\/3 of contents in the can are used up. Close the tap valve of the can. (Valve turns CW to open and CCW to close).\u003c\/li\u003e\n\u003cli\u003eIf no flow of the material is noticed when first opened, close the flushing kit tap valve, disengage the hose connector from the service port, and adjust the depressor inside the hose connector outward by 1 or 2 turns, and repeat the steps 5 through 7 above.\u003c\/li\u003e\n\u003cli\u003eNow it is time to quickly connect LIQUID SIDE copper pipe (one with smaller diameter) to the LIQUID side service valve of the outdoor unit properly and as instructed in the equipment installation manual, using proper torque, methods and materials approved by the equipment manufacturer. At this stage all 4 pipe connectors are tightly connected.\u003c\/li\u003e\n\u003cli\u003eOpen the tap valve again and release the remaining material in the can into the system until contents are entirely used up. Disconnect the hose from the service port of the unit.\u003c\/li\u003e\n\u003cli\u003eUsing soapy bubbles spray, carefully check all 4 pipe connections for leaks. If the leaks are present, tighten, adjust, or repair the connection to stop any leaks, and repeat evacuation.\u003c\/li\u003e\n\u003cli\u003eWhile the purging hose remains attached to the service port, unscrew the tap valve from the top of the canister to release all remaining gas pressure, and wait until all purging material pressure is entirely released. Disconnect the hose from the service port.\u003c\/li\u003e\n\u003cli\u003eFollow the installation instructions provided by the equipment manufacturer for the next steps, such as opening the service valves to release the refrigerant, other verifications, and further startup procedures. For multi-zone systems, use one kit for each zone.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eWARNING for California residents only: \u003cspan style=\"color: #000000;\"\u003eThis product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eWarning: Use only as directed. Read label instructions carefully.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eKeep out of reach of children. Intentional misuse by deliberately concentrating and\/or inhaling contents may be fatal. Vapors are heavier than air and may spread along floors. Avoid breathing vapors or mist. Avoid contact with skin, eyes, and clothing. Provide sufficient air exchange and \/or exhaust in work areas. Handle in accordance with good industrial hygiene and safety practice. THIS PRODUCT IS FOR OUTDOOR USE ONLY.\u003c\/li\u003e\n\u003cli\u003eContains gas under pressure, may explode if heated. Flammable gas. Do not spray on an open flames or other ignition sources. Keep away from heat. Vapors may form flammable mixture with air. The products should only be used in areas from which all sources of ignition have been excluded. Electrical equipment should be protected to the appropriate standard. No sparking tools should be used. Take measures to prevent the build-up of electrostatic charge. Keep away from open flames, hot surfaces, and sources of ignition. When using DO NOT SMOKE. Disconnect the electrical power to the equipment.\u003c\/li\u003e\n\u003cli\u003ePressurized container: Do not pierce or burn, even after use. Do not store in enclosed vehicles. Protect from sunlight. Store in a well-ventilated place. Store at temperatures not exceeding 120 degrees F \/ 49 degrees C. Keep container tightly closed and in a dry and well-ventilated location. Store in original container. The product has and indefinite shelf life when stored properly.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation, especially in confined areas. Use respiratory protection if needed. Wear safety glasses with side shields. Direct contact with liquid may cause frostbite. Wear proper protective gloves when using.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eContains: 1,1-Difluoroethane which has zero ozone depletion potential and a very low global warming potential. See MSDS for additional safety information at \u003ca href=\"https:\/\/www.pdhvac.com\"\u003ehttps:\/\/www.pdhvac.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"a-list-item\"\u003e\u003cspan\u003e⚠️ \u003cstrong data-start=\"72\" data-end=\"88\"\u003ePlease Note:\u003c\/strong\u003e Internal components and consumables are \u003cem data-start=\"129\" data-end=\"141\"\u003efinal sale\u003c\/em\u003e and \u003cstrong data-start=\"146\" data-end=\"188\"\u003enon-returnable under any circumstances\u003c\/strong\u003e, whether purchased under warranty or not. Be absolutely certain of compatibility before ordering—when in doubt, contact our support team for assistance. Refer to the \u003ca href=\"https:\/\/www.pioneerminisplit.com\/pages\/returns-and-refunds\" title=\"Return and Refund Policy\" rel=\"noopener\" target=\"_blank\"\u003eReturn Policy\u003c\/a\u003e for more details.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eInstructional Video\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ZDXIIJwDkM8\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Pioneer Official Store","offers":[{"title":"Default Title","offer_id":43805067182116,"sku":"IKT-KEV-10-516","price":34.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0254\/3914\/1924\/files\/kwik00.jpg?v=1773424600","url":"https:\/\/www.growitdepot.com\/products\/kwik-e-vac-line-set-flushing-kit-installation-simplifier-for-mini-split-air-conditioning-systems","provider":"Grow It Depot","version":"1.0","type":"link"}